SECTION 5 t,_O 
FENESTRATION SYSTEM 
WINDOWS 
& SKYLIGHTS 
SYSTEM 
CONDITION 
ASSESSMENT 
Protect What Lets Light In-Keep 
Water Out . 
...., 
G) SYSTEM CONDITION 
ASSESSMENT 
RATING 
0ESCRIP'TION 
0 
Compononts are doan. woothor-tight. 
Excellent 
and operating proporly. 
C, Good 
Minor weathering consistent with ege. 
Continuo routino rnaintona.nco. 
Early deterioration or maintenance 
Fon-
needs observed. Preventivo 
maintenance recommonded. 
0 Poor 
Visible deterioration affecting weather 
resistance or operation. 
0 Critic.ii 
Active water intrusion, broken glaring, 
structural concerns, or safety hazards 
requiring immediate attention, 
© DOCUMENTATION 
Photographs Taken? 
Photograph: 
All bulldrng elevations 
Representative windows 
• Skylights 
Sealant joints 
• Water staining 
• Damaged screen• 
• Areas requiring maintenance 
0 Yes 
0 No 
m 
0 7 PROPERTY STEWARDSHIP IN PRACTICE 
The Leak Wasn't the Window 
A homeowMt noticed wat6t staining benoath a wdroom window 
eftor se.,.,.1 Storms and a.sumod tho window .u.lf hod f;;Uod. 
During • profoulonal inspection, the glass and framo wont found 
to be in good condition. TIM actual problem wu doteriorotod 
..,olant ond improporly functioning fluhing at the hood of tho 
window, allowing ,olnwator to enter behind the trim. 
The ropalr involved ropt.cing the fa!led sealant, correcting tho 
flashing, and r01toring tho affocted trim. 
0 The window was never the problem. 
The surrounding weatherproofing 
system was. 
Routine inspection.• of sealants and flashing could have identified 
the issue before interior damage occurred. 
@ EXPECTED SERVICE LIFE' 
COMPONENT 
Aluminum window from•s 
Vinyl window frames 
Wood window frames (maintained) 
lnwlat•d glass units 
Skytighu 
Exterior sealants 
Weatherstripping 
Window screons 
lYPICAl. SERVICE LIFE" 
30-45years 
20-35 years 
JO-.SO+years 
20-30 years 
20-JOyHrs 
S-1S years 
10-20 years 
10-20yurs 
@ RECOMMENDED 
@ PRIORITY LEVEL 
© 
No Action Required 
0 
Monitor and address 
I-
Low 
during routine 
0 
0 
~ Continue Monitoring 
0 
maintenance. 
~ 
Routine Cleaning 
0 
Address within 
0 
~ Mc::llum 
0 
A 
Sealant Replacement 
0 
6-12 months. 
X 
Hardware Adjustment 
0 
0 
I-
Addross as soon as 
& 
Professional Window Service 
0 
High 
practical. 
0 
0 
4 
Flashing Repair 
0 
m Replacement 
Planning 
0 
I-
Address immediately to 
Immediate 
prevent further damage 
D 
D 
or safety risk. 
® INSPECTOR'S NOTES 
@ WHY THIS MATTERS 
Observed Conditions: 
Recommendations: 
' ' , 
-,(ij,-STEWARDSHIP TIP 
After periods of heavy wind-driven rain, 
inspect the interior around windows 
and skylights for subtlo signs of 
moisture, including stoining, pooling 
paint, soft drywall, or condensation . 
Small changes often provide the 
eorfiest indication of developing 
wator intrusion. 
Windows and skylights am among the most common locations 
for water intrusion-not 
because tho glass falls, but b<>causo 
surrounding sealants, flashing, dreinago paths, and framing 
deteriOf'ate over time. 
Regular inspections help identify these issues before they 
lead to hidden moisture damage within the wall assembly. 
Maintaining clean glazing, functional drainage, and weather-tight 
perimoter seals also improves energy performance, occupant 
comfort, and the long-term appearance of tho property. 
& WHEN TO CONTACT A QUALIFIED PROFESSIONAL 
Arrange a professional evaluation if you observe: 
• Cracked or broken glazing. 
• Persistent fogging between insulated glass panes. 
• Active water i.ntrusion. 
• Repeated interior staining beneath windows or skylights. 
• Deteriorated flashing. 
• Failed perimeter sealants. 
• Significant frame corrosion or wood decay. 
• Windows that no longer OpGn, close, or lock property. 
• Loose or damaged skylights following severe weather. 
@ 
ANNUAL FENESTRATION SYSTEM INSPECTION SUMMARY 
AdualHnlb 
lifodopet,dson 
inotallotlonquality. 
-· 
malnttnonoo 
p,ac:tioes. 
matecill 
IOledion.and 
..__.,_ -
Overall Systom Condition: 0 Excellent O Good O Fair O Poor O Critical 
Highest Priority Action: __________________ 
_ 
Recommended Complelion Date: _______________ 
_ 
Next S<:heduled Inspection: _________________ 
_ 
Inspector: _______________________ 
_ 
SECTION 5 
(WINDOWS & SKYLIGHTS) SYSTEM CONDITION ASSESSMENT 
• 'r 
STEWARDSHIP TODAY VALUE TOMORROW 

View this content as a flipbook by clicking here.